Mallory-ignition Mallory Hyre 6EZ and 6EZ RPML 6855M_6856M User Manual

Browse online or download User Manual for For the car Mallory-ignition Mallory Hyre 6EZ and 6EZ RPML 6855M_6856M. Mallory Ignition Mallory Hyre 6EZ and 6EZ RPML 6855M_6856M User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Part#: 6855M, 6856M

Hyre 6EZ and 6EZ RPMLInstruction ManualPart#: 6855M, 6856M

Page 2 - 6EZ and 6EZ RPML SERIES

HYFIRE®DE SÉRIES 6EZ ET 6EZ RPMLCOMMANDE D’ALLUMAGE ÉLECTRONIQUEPIÈCES Nos 6855M (6EZ) et 6856M (6EZ RPML)VEUILLEZ LIRE TOUTES LES INSTRUCTIONS AVANT

Page 3 - MOUNTING

SoudagePour éviter d’endommager la commande d’allumage HYFIRE®6EZ lors des soudures sur le véhicule, débrancher les câblespositif (rouge) et négatif (

Page 4

CÂBLAGE Voir la Figure 2Déposer le câble de la bobine du fabricant et le mettre de côté.Laisser en place tous les autres câbles du distributeur et de

Page 5 - TROUBLESHOOTING

Réglages du limiteur de régime 6EZ RPML seulement, voir la figure 3Repérer l’étiquette attachée à la plaque d’extrémité du HYFIRE®EZ RPML. Cette étiqu

Page 6 - INSTRUCCIONES DE INSTALACIÓN

TROUBLESHOOTING GUIDE FORCAPACITIVE DISCHARGE (CD) IGNITION SYSTEMSMost CD boxes operate the same way, making forcommon basic test procedures. Most C

Page 7 - FIGURA 1

7. If both of these tests prove out, then the problem iseither in the distributor, crank trigger, or the wiringis incorrect.TESTING THE COILNOTE: This

Page 8

HYFIRE®6EZ and 6EZ RPML SERIESELECTRONIC IGNITION CONTROLPART NOS. 6855M (6EZ) and 6856M (6EZ RPML)PLEASE READ THESE INSTRUCTIONS COMPLETELY BEFORE ST

Page 9 - Posición ABAJO ARRIBA

mark the location of the mounting holes. Use a 1/8" drill bit to drillthe holes. Use the supplied self-tapping screws to mount the box.The ProMas

Page 10 - DE SÉRIES 6EZ ET 6EZ RPML

WIRING See Figure 2Remove the factory coil wire and set it aside. Leave all otherwiring on the distributor and coil in place. Connect one of the 2supp

Page 11 - Mallory-Ignition.com

Rotary Switch Switch #1 Switch #1Position DOWN UP0 4,500 8,5001 4,750 8,7502 5,000 9,0003 5,250 9,2504 5,500 9,5005 5,750 9,7506 6,000 10,0007 6,250 1

Page 12 - PART No. 6855

CONTROL DE ARRANQUE ELECTRÓNICOHYFIRE®SERIES 6EZY 6EZ RPMLNÚMEROS DE PIEZAS 6855M (6EZ) y 6856M (6EZ RPML)SÍRVASE LEER ESTAS INSTRUCCIONES COMPLETAMEN

Page 13 - DÉPANNAGE

guantera. Cuando consiga una ubicación apropiada para montarla unidad, asegúrese de que los cables del arranque alcancen lasconexiones. Sujete el arra

Page 14 - TROUBLESHOOTING GUIDE FOR

CABLEADO (consulte la figura 2)Quite el cable de la bobina instalada en fábrica y póngalo a unlado. Deje todos los demás cables del distribuidor y la

Page 15

Valores del limitador de RPM 6EZ RPML solamente vea la figura 3Observe la calcomanía adherida a la placa terminal del HYFIRE®6EZ RPML. Esta calcomaní

Comments to this Manuals

No comments